DHTML JavaScript Website Pull Down Navigation Menu By Milonic

Johnson Systems Inc.

<b>UDC-24</b> Universal Dimmer Controller

RetrofitCHARACTERISTICS

Power Requirements: 120/208V 3 phase or 120/240V single-phase at 50 or 60 Hz. Maximum current 1 Amp.

Environment: Temperature Range: 23° F. ( -5° C.) to 113° F. ( 45° C.) ambient. Humidity Range: 0% to 90% non-condensing.

Physical: 17.5" W x 9.5" D x 1.75" H (44.5cm x 24.1cm x 4.4cm).

Weight: Approximately 7 lbs. (3.2 Kg).

Material: 18 gauge CRS.

Finish: Fine texture black powdercoat.

SPECIFICATIONS

1. Each UDC-24 system controller shall be capable of driving up to 24 individual phase controllable SSR's with an input control requirement not exceeding 20mA each. One DB25 output connector shall contain all 24 PMW outputs. An optional interface PCB and wall mount enclosure shall permit the use of CAT5E wiring and remote signal distribution up to 1000'. Termination via punch-down or RJ-45 shall be optional.

2. Control input protocol shall be standard USITT DMX-512A and/or 0-10 Volt DC analog. A total of 24 separate/isolated analog inputs shall be provided. UDC-24's output shall be highest takes precedence (HTP) of the input control signals. The DMX input shall be fully opto-isolated for controller protection up to 2500 Volts. The UDC-24 shall contain RMD compliant hardware.

3. The UDC-24 system controller shall contain a backlit LCD display and five (5) buttons to allow simple user interface for programming and system testing.

4. Each UDC-24 system controller shall have dual switching power supplies capable of 85-265VAC at 50 or 60 Hz.

5. All connections shall be via premium "breakaway" style connectors. It shall not be necessary to re-wire any portion of the control electronics to facilitate system repair or replacement.

6. It shall be possible to program the following system functions without any proprietary programmers, software or a PC:

7. It shall be possible to view the following system functions on the system LCD via simple and intuitive menuing without any proprietary programmers, software or a PC:

8. A keypad lockout feature shall permit electronic lock/unlock of the controller keypad.

9. The systems controller shall contain status L.E.D. indicators of correct line voltage, phase reference voltage, DMX receive, output level, and system over-temp.

10. Control electronics shall contain the necessary hardware for future implementation of both RDM (ESTA Remote Device Management) and JDM (Johnson Device Management).

Specifications subject to change without notice.

info@johnsonsystems.com